Environmental Stress Screening Test Chambers
Temperature change rates from of 3, 5, 10, 15 or 18K/min.
Advanced Reliability
Lab Companion T/C series has a large tolerance for heat loads generated by the specimen, and achieves improved temperature change rate in an expanded temperature and humidity range.
The new N-instrumentation allows AR series chambers to support an easy-to-use networking system.
- Two product types
-
- Rapid-Rate Temperature Cycle Type
- 6K/min per IEC 60068-3-5 (meeting the performance requirement of 5K/min. such as IEC 60068-2-14Nb.) NEW!
- Standard Type
The product lineup consists of 28 models that can be selected in accordance with temperature & humidity range, inside capacity and temperature change rate.
Test Standard Conformance
IEC 60068-2-1 : Cold
IEC 60068-2-2 : Dry heat
IEC 60068-2-14 Nb : Change of temperature with specified rate of change
IEC 60068-2-30 : Damp heat, cyclic (Rapid-Rate Temperature Cycle Type)
IEC 60068-2-38 : Composite temperature/ humidity cyclic test
IEC 60068-2-78 : Damp heat, steady state
ISO 16750-4(5.3) : Road vehicles, Temperature cycling tests
- Wide temperature range up to 200°C
- High temperature testing up to +200°C is possible (option).
- International safety standards
- Conforms to ISO12100 and IEC60204, IEC61000 and EN50581 to CE marking requirements based on EU directives: Low voltage directive, EMC directive, machinery directive, pressure equipment directive, and RoHS directive.
- Remote monitoring and control thanks to a web application
- No software required, an innovative web browser application allows to monitor and control the chamber with a computer via the chamber standard Ethernet/LAN port. Mobile PC, tablet, and smart phone with multiple chamber connections possible by wireless connection.
- Email alert
- When an alarm is triggered, an e-mail is sent to the registered PC or mobile address. A notification can also be sent at the time of test completion.
- Copy your test programs, output data on USB memory
- Temperature & humidity range
-
Minimum temp.: -70°C
Maximum temp.: +180°C
Humid.: 10 to 98%rh
- Totally frost-free
- Frosting will not appear on any part of the unit despite the temperature & humidity control range of range from 10 to 98%rh. Eradicating the need to remove frosting provides stable and continuous operations.
- Big tolerance for heat load
-
Temperature only: up to 9000W
Temp. & humid.: up to 550W
Allowable heat load is different depends on models and operation conditions. Please refer to our brochure for the details. - Energy-saving with Dual PID Control
- Dual PID Control (Proportional-Integral-Differential: control that enables the segmentation of refrigeration capacity) mostly controls only the refrigerator at 0°C or lower, thereby saving energy.
- Specimen temperature control (optional)
- Attaching a temperature measurement sensor to the specimen enables the temperature of the specimen to be monitored and controlled.
- Easy access to specimen
-
Equipped with cable ports on both right & left sides as standard.
Door notch port is also available to put cables through the door (option). - N-instrumentation equipped with a color LCD touch panel
- Arge screen with LED backlight is clearer and provides faster display speed.
- -70 to +180°C (10 to 98%rh)
-
Model Interior
VolumeInterior
Dimensions
(mm)Exterior
Dimensions
(mm)Performance Temp. & Humid. Temp. Only Time to Reach Extreme Temp. Temp. Change Rate per
IEC 60068 3-5/ 3-6C/270/70/10 T/270/70/10 270L W580
H750
D615W895
H1950
D2080+20 → +180°C:
20 min.
+20 → -70°C:
20 min.No
Specimen-45 ? +155°C
Heat-up Rate &
Pull-down Rate:
10°C/min.C/270/70/15 T/270/70/15 +20 → +180°C:
15 min.
+20 → -70°C:
15 min.No
Specimen-45 ? +155°C
Heat-up Rate &
Pull-down Rate:
18°C/min.C/480/70/10 T/480/70/10 480L W800
H950
D650W1115
H2090
D2605+20 → +180°C:
20 min.
+20 → -70°C:
20 min.No
Specimen-45 ? +155°C
Heat-up Rate &
Pull-down Rate:
10°C/min.C/480/70/15 T/480/70/15 +20 → +180°C:
15 min.
+20 → -70°C:
15 min.No
Specimen-45 ? +155°C
Heat-up Rate &
Pull-down Rate:
15°C/min.C/800/70/10 T/800/70/10 800L W1000
H980
D800W1410
H2085
D2815+20 → +180°C:
20 min.
+20 → -70°C:
20 min.No
Specimen-45 ? +155°C
Heat-up Rate &
Pull-down Rate:
10°C/min.C/800/70/15 T/800/70/15 +20 → +180°C:
15 min.
+20 → -70°C:
15 min.No
Specimen-45 ? +155°C
Heat-up Rate &
Pull-down Rate:
15°C/min.C/600/70/5 T/600/70/5 600L W800
H950
D800W1115
H1955
D1855+20 → +180°C:
40 min.
+20 → -70°C:
40 min.No
Specimen-45 ? +155°C
Heat-up Rate &
Pull-down Rate:
6°C/min.C/1000/70/5 T/1000/70/5 1000L W1100
H950
D950W1415
H2000
D2030+20 → +180°C:
40 min.
+20 → -70°C:
40 min.No
Specimen-45 ? +155°C
Heat-up Rate &
Pull-down Rate:
6°C/min.
Without the need of a PC, copy and transfer your test profiles from one chamber to another. You can also download temperature and humidity data from the chamber for editing on your PC.
Rapid-Rate Temperature Cycle Type New!
Temperature change rate
Capacity | 270L | 480L | 600L | 800L | 1000L | |||
---|---|---|---|---|---|---|---|---|
Temp.range | -45?+155°C | |||||||
Heat up Pull down |
10K/min. 10K/min. |
18K/min. 18K/min. |
10K/min. 10K/min. |
15K/min. 15K/min. |
6K/min. 6K/min. |
10K/min. 10K/min. |
15K/min. 15K/min. |
6K/min. 6K/min. |
* C: temperature & humidity, T: temperature only